Brand Name : SST
Model Number : LOX-02-F L0X-O2-F
Place of Origin : Britain
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 2200
Delivery Time : 3 days
Packaging Details : boxed
Supply voltage (Vs) : 4.5-5.5 Vdc
Supply current (ls) : <7.5mA (single sample per second streaming)
Output Type : 3.3V TTL level USART
Operating temperature : -30°C ~ +60°C
Storage temperature : -30°C ~ +60°C
Product Description:
LOX-02-F L0X-O2-F UK Fluorescent Oxygen (O2) Sensor 0-25% For Medical Use
Features:
LuminOx Flow-through optical oxygen sensors allow clean gas to Flow directly into the sensor and can be completely removed from the process environment.
Long service life Low power consumption low maintenance oxygen sensor
peculiarity
Luminescence based optical technology, non-electrochemical
Factory calibrationExtended temperature range
maintenance-free
Battery powered
No extra electrons required
Small size
LuminOx Flow-through optical oxygen sensors allow clean gas to Flow directly into the sensor and can be completely removed from the process environment.
Developed and manufactured by SST, LuminOx Flow-through optical oxygen sensors are part of the LuminOx family, a series of factory-calibrated oxygen sensors that measure ambient oxygen content using the principle of fluorescence quenching (also known as luminescence quenching).
The LuminOx Flow-through Optical Oxygen Sensor (LOX-02-F) is an extension of the LuminOx standard range of oxygen sensors with a faster response.
The straight-through housing is sealed on the base, allowing clean sample gas to flow directly into the sensor. The sensor can be completely removed from the process environment. The straight-through housing allows for better sample gas management and sensor location selection.
SST has the technology to produce a range of sensors based on non-expendable operating principles. This technology gives LuminOx sensors a longer service life than other competing technologies.
Every LuminOx oxygen sensor has an internal sensor for temperature and air pressure compensation, which means customers don't need to consider this when designing. It can also communicate directly with the customer's USART, so there is no need for signal conditioning circuits.
LuminOx is a completely solid-state sensor that contains no lead or liquid electrolytes and is 100 percent RoHS compliant. It has little cross-sensitivity and can be used in applications where the presence of specific gas mixtures makes it unreliable with other techniques.
The luminescence quenching principle measures the partial pressure of oxygen (ppO2). Internal pressure sensor measurements and ppO2 measurements allow oxygen concentration (O2%) values to be calculated. The USART output allows the sensor to transmit values of O2%, ppO2, atmospheric pressure, internal temperature, and sensor status.
Specifications:
| Humidity | 0-99%Rh (non-condensing) | 
| Pressure range | 500-1200mbar | 
| Maximum flow rate | 1.0 L/min | 
| Oxygen range | 0-25% O₂ | 


|   | 
| YJJ LOX-02-F L0X-O2-F UK Fluorescent Oxygen O2 Sensor 0-25% For Medical Use Images | 
 H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
                                                                                        
                                                        
                        
                        
                        
                                                            H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
                                                    
                        
                     NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
                                                                                    
                        
                        
                        
                                                            NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
                                                    
                        
                     H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
                                                                                    
                        
                        
                        
                                                            H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
                                                    
                        
                     NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
                                                                                    
                        
                        
                        
                                                            NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
                                                    
                        
                     NO-A1 Nitric Oxide Sensor (NO sensor) Is Used For Automobile Exhaust Detection
                                                                                    
                        
                        
                        
                                                            NO-A1 Nitric Oxide Sensor (NO sensor) Is Used For Automobile Exhaust Detection
                                                    
                        
                     NH3/CR-50 Ammonia Detection Sensor Highly Sensitive NH3 Measurement 3 Electrode
                                                                                    
                        
                        
                        
                                                            NH3/CR-50 Ammonia Detection Sensor Highly Sensitive NH3 Measurement 3 Electrode
                                                    
                        
                     SR-H-MC ACU01-U00 MICROceL H2S Hydrogen Gas Sensor Three Electrode Electrochemis
                                                                                    
                        
                        
                        
                                                            SR-H-MC ACU01-U00 MICROceL H2S Hydrogen Gas Sensor Three Electrode Electrochemis
                                                    
                        
                     GS+4NO2 Nitrogen Dioxide NO2 Gas Sensor 4 Series 3PIN Use In Industry
                                                                                    
                        
                        
                        
                                                            GS+4NO2 Nitrogen Dioxide NO2 Gas Sensor 4 Series 3PIN Use In Industry
                                                    
                        
                     SR-W-MP75C Micropel 75C Combustion Gas Sensor Catalytic Oxidation
                                                                                    
                        
                        
                        
                                                            SR-W-MP75C Micropel 75C Combustion Gas Sensor Catalytic Oxidation
                                                    
                        
                     TGS826 NH3 Ammonia Gas Detector Sensor Low Conductivity Resistance To Environmen
                                                                                        
                                                        
                        
                        
                        
                                                            TGS826 NH3 Ammonia Gas Detector Sensor Low Conductivity Resistance To Environmen