| Sign In | Join Free | My insurersguide.com |
|
Model Number : SO2-AE SO2-AF
MOQ : 1
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time : 3-5work days
Place of Origin : Germany
Price : Negotiable
Supply Ability : 5000pcs
Packaging Details : Paper box
Sensitivity : 55 to 80
Response time : < 25
Zero current : < 5
Resolution : < 1.5
Range : 2,000
Linearity : 0 to -80
SO2-AE Electrochemistry Sulfur Dioxide Sensor High Concentration Used For Flue Gas Detector Automobile Exhaust Monitor Various Sulfur Dioxide Detection Occasions
The SO2 range provides OEMs with reliable sensors for use in a variety of applications. Strong signal levels combined with low zero current allows resolution below 1ppm and an operating range for safety applications up to 2,000ppm. The sensors are designed for use in both fixed site and portable instrumentation.
The SO2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.
| SO2-AE Sulfur Dioxide Sensor SO2 Sensor PERFORMANCE | ||
| Sensitivity | nA/ppm in 400ppm SO2 | 55 to 80 |
| Response time | t90 (s) from zero to 400ppm SO2 | < 30 |
| Zero current | ppm equivalent in zero air | < ±5 |
| Resolution | RMS noise (ppm equivalent) | < 1.5 |
| Range | ppm limit of performance warranty | 2,000 |
| Linearity | ppm error at full scale, linear at zero and 400ppm | 0 to -80 |
| Overgas limit | maximum ppm for stable response to gas pulse | 10,000 |
| SO2-AE Sulfur Dioxide Sensor SO2 Sensor LIFETIME | ||
| Zero drift | ppm equivalent change/year in lab air | < 0.2 |
| Sensitivity drift | % change/year in lab air, monthly test | < 4 |
| Operating life | months until 80% original signal (24 month warranted) | > 24 |
| SO2-AE Sulfur Dioxide Sensor SO2 Sensor ENVIRONMENTAL | ||
| Sensitivity @ -20°C | % (output @ -20°C/output @ 20°C) 400ppm | 80 to 92 |
| Sensitivity @ 50°C | % (output @ 50°C/output @ 20°C) 400ppm | 98 to 108 |
| Zero @ -20°C | ppm equivalent change from 20°C | < ±3 |
| Zero @ 50°C | ppm equivalent change from 20°C | < ±4 |
| SO2-AE Sulfur Dioxide Sensor SO2 Sensor CROSS SENSITIVITY | ||
| Filter capacity | ppm·hrs H2S | < 5,000 |
| H2S sensitivity | % measured gas @ 20ppm H2S | < 2 |
| NO2 sensitivity | % measured gas @ 10ppm NO2 | < -200 |
| Cl2 sensitivity | % measured gas @ 10ppm Cl2 | < -60 |
| NO sensitivity | % measured gas @ 500ppm NO | < 25 |
| CO sensitivity | % measured gas @ 400ppm CO | < 10 |
| H2 sensitivity | % measured gas @ 400ppm H2 | < 1.5 |
| C2H4 sensitivity | % measured gas @ 1000ppm C2H4 | < 40 |
| NH3 sensitivity | % measured gas @ 20ppm NH3 | < 0.1 |
| SO2-AE Sulfur Dioxide Sensor SO2 Sensor KEY SPECIFICATIONS | ||
| Temperature range | °C | -30 to 50 |
| Pressure range | kPa | 80 to 120 |
| Humidity range | % rh continuous | 15 to 90 |
| Storage period | months @ 3 to 20°C (stored in sealed pot) | 6 |
| Load Resistor | Ω (recommended) | 10 to 47 |
| Weight | g | < 6 |

|
|
SO2-AE SO2-AF Electrochemistry Sulfur Dioxide Sensor High Concentration Used For Flue Gas Detector Automobile Exhaust Monitor Various Sulfur Dioxide Images |