Brand Name : YJJ
Model Number : AWM42100VH
Place of Origin : USA
MOQ : 1
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1500
Delivery Time : 5-8 days
Packaging Details : Palletized
Accuracy : ±0.30% reading
Repeatability & Lag : ±0.35% reading
Response time : 1 ms
Pressure drop : 0.49 mbar
Temperature compensation : Built-in thermistor (-25~85℃)
Operating temperature : -25~85℃
Storage temperature : -40~90℃
Protection level : Requires an external 5μm filter for dust protection
Product Description:
YJJ AWM42100VH Gas Flow Sensor Is Used In Fields Such As Industrial Automation And Environmental Monitoring
Features:
AWM40000 series gas flow sensors include signals without amplification and amplification or signal processing. The gas flow sensor has an electric bridge structure consisting of a heater and a temperature sensitive element. The bridge type structure has a sensitive and fast response to the flow of air or other gas flowing through the chip. 6slpm device. Its main features are:.The latest micromachining technology. The maximum detection flow rate 0-6slp. The working temperature can reach 125 degrees C. The highest can bear the co membrane pressure of 150psi. Fast response, low current loss. Zero and full range high stability applications: cable inflator, medical ventilator and vital capacity apparatus, gas detection equipment, gas calibration
FEATURES
  · Ranges 0...±25 and 0...±1000 sccm1
  · Bidirectional sensing
  · Actual mass flow sensing
  · Ceramic flow tube
  · Manifold mount/o-ring sealed
  SPECIFICATIONS ELECTRICAL CONNECTION
  Maximum ratings
  Supply voltage2 8 to 15 V
  typ. 10 ±0.01 V
  Power consumption max. 60 mW
  Temperature limits
  Operating -40 to 125°C
  Storage -40 to 125°C
  Mechanical shock 100 g (5 drops, 6 axes)
  1 2 3 4 5 6
  P 1 P 2
  Note:
  1 sccm denotes standard cubic centimeters per minute
  2 Output voltage is ratiometric to supply voltage
  SERVICE
  To be used with dry gases only.
  The AWM42150VH is a special sensor for
  hydrogen (H2) flow.
  The AWM series is NOT designed for liquid
  flow and will be damaged by liquid flow through
  the sensor.
  2/6 November 2004 / 624
  AWM42000 Series
  Mass flow sensor for gases
  Part no. Flow range
  (full scale)
  Max. flow
  change4
  Output voltage
  @ trim poin
  AWM42150VH ±25 sccm 5.0 l/sec 8.5 ±1.5 mV @ 25 sccm
  AWM42300V ±1000 sccm 5.0 l/sec 54.7 ±3.7 mV @ 1000 sccm
  PERFORMANCE CHARACTERISTICS
  VS = 10 ±0.01 V, TA = 25°C
Specifications:
| Supply voltage2 | 8 to 15 V | 
| typ. | 10 ±0.01 V | 
| Operating | -40 to 125°C | 
| Storage | -40 to 125°C | 

|  | 
| YJJ AWM42100VH Gas Flow Sensor Is Used In Fields Such As Industrial Automation And Environmental Monitoring Images |